Full Address: Rushcliffe Borough Council, Loughborough Road, West Bridgeford, Notts, NG2 7JE
Site: West Park (A1471)
Equipment: FLYGT PUMP STATION
Description:
Please could they call 07970 272038 at least 30 mins prior to their arrival to allow the team enough time to meet on site. Service - Following the other two
Full Address: W Leake Ln, Kingston on Soar, Nottingham NG11 0DN, UK
Site: West Leake Lane, Kingston on Soar
Equipment: Klargester BE
Description:
Service - Following on from the crem with their tanker On the last visit Gary suggested filling in the bottom of the tank with concrete due to a split - This has been assessed as not the best option and we would need to know volumes if this was to be done. Please assess see if it can be fiberglass or repaired in a different way. If it is concrete please take details to provide full quotation
2 man 4 hours Tanker - Site have requested to empty only then bung it off - they will ensure nothing comes into the tank - Camion Hose lay 50m Extra high pressure jetter for 1 hour Site not to use facilities and not to be raining as surface water gets into unit. Tank entry Ladders 1x 601ne 20m cable and Take the 20m cable to replace the cable installed 25/3 Pipework 2.5 inch Straight pipe 3m Socket union x4 Bsp x2 Brass Nrv x2 Just in case 2x 90: 1x T 1x threaded threaded 1x gate valve brass Chain quoted due to rust Nrvs have partially failed and need replacing Pumps are very low on ir and need replacing Site have purchased their own lifting chain and D links and would like us to install
Full Address: Stubby Ln, Draycott in the Clay, Ashbourne DE6 5BU, UK
Site: 73 STUBBY LANE
Equipment: WPL with Pump
Description:
Quote 07065 Fuji 200 1Eng 1 hr SITE: 73 Stubby Lane, 73 Stubby Lane, Marchington, Staffordshire DE6 5BU JOB SPEC: Engineer attendance required to install a new compressor due to the current one failed and broken ORDER NUMBER: 2503128
Full Address: 1 - 7 Gwens Grove, Bearley, Stratford-upon-Avon CV37 0TR, UK
Site: Gwens Grove
Equipment: Pump station
Description:
Quote 2 x contactors Lovato BG0910A 4 x 27mm od guild rails 3 m each 4 x 150mm SS M8 bolt 8 x M8 SS washers 4 x M8 SS nuts 2 man 3 hrs Engineer will need 8mm drill bits to drill through cast iron.
Full Address: 1 - 7 Gwens Grove, Bearley, Stratford-upon-Avon CV37 0TR, UK
Site: Gwens Grove
Equipment: Pump station
Description:
Following attendance over the weekend, the alarm has been sounding constantly and the emergency light flashing. Can you please arrange for re-attendance today to rectify
Full Address: Stubby Ln, Draycott in the Clay, Ashbourne DE6 5BU, UK
Site: 73 STUBBY LANE
Equipment: WPL with Pump
Description:
SITE: 73 Stubby Lane, 73 Stubby Lane, Marchington, Staffordshire DE6 5BU JOB SPEC: Attend site to undertake a routine maintenance check on the control panel that has a potential fault. The air pumps are making a loud noise again which sounds like it is the impeller, the same as last time ORDER NUMBER: 2503115
Full Address: Collegiate Cres, Broomhall, Sheffield S10 2BR, UK
Site: Mr Fee - 45 Collegiate Cres
Equipment: Single Pump Station
Description:
Crude Ksb501se 2 inch Cable started to blow on pump. Check ir on pump next service and see if it needs replacing. John has quoted to change rubber joint in tank as it is leaking. Tested today and minimal leaking customer would still like changed on next service 2 inch Threaded plain nipple Brass Nrv Bsp Socket union Straight pipe 30cm 2 man extra hour on service. Concrete mixing pad to stop mess. Buckets to empty out water as when pipework gets cut everything above Nrv going to come back i
Booked for 1.30-3.30 NS - Callout to pump station not working - They have confirmed with Esther they have sorted the lid A few notes for the engineer; - Pumping only appeared to happen at the highest float switch level (of the 4 float switches) - The water level was reduced to a low level using the manual mode on both pumps. After doing this both pumps stopped working. - Now, both pumps make a noise but arent pumping anything. - We have purchased a separate pump and so the water level will be low when the engineer arrives but not fully empty. - No red lights have shown on the console during any of the above.